The Huawei SmartAX MA5800 series OLT products include four models: MA5800-X17 FTTH Fiber OLT, MA5800-X15, MA5800-X7, and MA5800-X2.
Supports interfaces such as GPON, XG-PON, XGS-PON, EPON, 10G EPON, XG-PON&GPON combo, XGS-PON&GPON combo, Flex PON, GE, 10GE, etc.
Specification
|
FTTH Fiber OLT Item |
MA5800-X17 |
MA5800-X15 |
MA5800-X7 |
MA5800-X2 |
|
Dimensions (W x D x H) |
493 mm x 287 mm x 486 mm |
442 mm x 287 mm x 486 mm |
442 mm x 268.7 mm x 263.9 mm |
442 mm x 268.7 mm x 88.1 mm |
|
Switching Capacity of the System |
7 Tbit/s |
480 Gbit/s |
||
|
Maximum Number of Ports in a Subrack |
272 x GPON/EPON |
240 x GPON/EPON |
112 x GPON/EPON |
32 x GPON/EPON |
|
816 x GE/FE |
720 x GE/FE |
336 x GE/FE |
96 x GE/FE |
|
|
136 x 10G GPON/10G EPON |
120 x 10G GPON/10G EPON |
56 x 10G GPON/10G EPON |
16 x 10G GPON/10G EPON |
|
|
136 x 10G GE |
120 x 10G GE |
56 x 10G GE |
16 x 10G GE |
|
|
544 x E1 |
480 x E1 |
224 x E1 |
64 x E1 |
|
|
Ambient Temperature |
-40°C to 65°C* |
|||
|
*: The MA5800 FTTH Fiber OLT can start up at a lowest temperature of -25°C and run at -40°C. The 65°C temperature refers to the highest |
||||
|
Working Voltage Range |
-38.4V DC to -72V DC |
DC power supply: |
||
|
-38.4V to -72V |
||||
|
AC power supply: |
||||
|
100V to 240V |
||||
|
Layer 2 Features |
VLAN + MAC forwarding, SVLAN + CVLAN forwarding, PPPoE+, and DHCP option82 |
|||
|
Layer 3 Features |
Static route, RIP/RIPng, OSPF/OSPFv3, IS-IS, BGP/BGP4+, ARP, DHCP relay, and VRF |
|||
|
MPLS & PWE3 |
MPLS LDP, MPLS RSVP-TE, MPLS OAM, MPLS BGP IP VPN, tunnel protection switching, TDM/ETH PWE3, and PW protection switching |
|||
|
IPv6 |
IPv4/IPv6 dual stack, IPv6 L2 and L3 forwarding, and DHCPv6 relay |
|||
|
Multicast |
IGMP v2/v3, IGMP proxy/snooping, MLD v1/v2, MLD Proxy/Snooping, and VLAN-based IPTV multicast |
|||
|
QoS |
Traffic classification, priority processing, trTCM-based traffic policing, WRED, traffic shaping, HqoS, PQ/WRR/PQ + WRR, and ACL |
|||
|
System Reliability |
GPON type B/type C protection, 10G GPON type B protection, BFD, ERPS (G.8032), MSTP, intra-board and inter-board LAG, In-Service |
|||
| Board supported FTTH Fiber OLT | |||
| Control Board | |||
| MPLB | It provides 4 GE/10GE upstream transmission ports and supports load sharing. By default, MA5800 connects to upstream network through the control board | ||
| MPLA | |||
| CKUA | Supports stratum-3 clock functions by working with MPLB and MPLA | ||
| Upstream interface board | |||
| NXED | Enhanced 8-port 10GE upastream interface board, supporting 10GE/GE Ethernet upstream transmission. NXED is used when upstream ports currently provided in MA5800 are not enough. | ||
| Universal interface board | |||
| CIUA | Provides synchronous time/clock signal input&output interfaces, alarm parameter/Boolean value input&output interface. RS485 serial ports, and provides transparent transmission Ethernet ports. | ||
| Service board | |||
| GPHF | Provides 16 GPON ports for access services | ||
| GPSF | Provides 16 GPON ports for home access services | ||
| XGHD | Provides 8 asymmetric 10G GPON ports for access services. | ||
| TWED | Provides 8 symmetric 10G GPON ports for access services. | ||
| EDSH | 32-channel E1 upstream board, supporting native TDM mode. | ||
| OGHK | 48-port aggregated GE/FE optical interface board, supporting up to 48 channels of GE/FE | ||
| OXHD | 8-port aggregated 10GE optical interface board, supporting GE/10GE Ethernet aggregation. | ||
| Power board | |||
| PILA | Provides -48V DC input | ||
| Fan Monitoring board | |||
| FMLA | Supplier power to fans; controls and moniotes the fans | ||
| FMMA | Supplier power to fans; controls and moniotes the fans | ||
| Dimensions (W x D x H) (mm) |
11 U high and 21 inch wide Excluding mounting brackets: 493x287x 486 Including mounting brackets: 535x287x486 |
||
| Maximum weight(including mounting brackets) | 45 kg | ||
| Maximum input current | 60 A | ||
| Power supply | Power supply mode: DC Working voltage range: -38.4 V to -72 V Rated voltage: -48 V / -60 V |
||
| Ambient temperature | -40°C to +65°C The MA5800 can start up at a lowest The MA5800 can start up at a lowest temperature of -25°C and run at -40°C. Note:The 65°C temperature refers to the highest temperature measured at the air intake vent of service subrack. |
||
| Ambient humidity | 5% RH to 95% RH | ||
FAQ
The main difference between MA5800-X7 and MA5800-X17 FTTH Fiber OLT lies in their specifications and functions.
MA5800-X17 is a high-performance OLT device that supports high-capacity 40GPON non blocking access, with a single slot throughput of up to 200G. It adopts a distributed forwarding architecture, which can meet the needs of 32000 households with 100Mbps non blocking access and is suitable for high-density deployment scenarios. In contrast, the MA5800-X7 FTTH Fiber OLT has lower specifications, but it is still a powerful OLT device that supports multiple access technologies such as GPON, XG-PON, XGS-PON, etc., making it suitable for small and medium-sized network deployments.
In terms of functionality and features, the MA5800 series devices support multiple network building modes such as FTTx and D-CAP, achieving full service integration access for home users, enterprise users, and mobile carriers. MA5800-X17 FTTH Fiber OLT emphasizes its distributed forwarding architecture and high throughput, while MA5800-X7 is more suitable for small and medium-sized network environments
M5800-X17 FTTH Fiber OLT slot description
| Slot classification | Slot position | Configurable single board | Remark |
| Main control board slot position | 9,10 | Main control board | Two slots need to be equipped with the same main control board, requiring dual main control boards |
| Power board slot position | 20,21 | Power supply board | |
| Universal interface board slot position | 0 | Universal interface board | |
| Business board slot | 1-8,11-19 | Upstream interface board / Business board | Support mixed configuration of different business boards / Upstream can be done through the main control board or the upstream interface board, and it is recommended to use the main control board for uplink |
Hot Tags: ftth fiber olt, China ftth fiber olt manufacturers, suppliers, fiber olt with electro optical switching, fiber olt with snmp support, fiber olt with long lifespan, fiber olt with nat support, fiber olt for fiber to the cabinet, fiber olt with bandwidth management