LC Fiber Patch Cords are used to connect devices to fiber optic cabling links.
LC fiber optic patch cables are commonly used with SFP and miniGBIC connectors in routers. They are high-speed, high-performance, and suitable for indoor use, meeting the design requirements of integrated cabling systems. LC-LC fiber optic patch cables are standard 2.0mm diameter fiber optic patch cables that meet and exceed ANSI/TIA/EIA-568 specifications.
Features of LC Fiber Patch Cords
1. 8-angle bevel polish;
2. Low insertion loss;
3. High reflection attenuation;
4. Standard metal components and a zirconium dioxide ceramic ferrule;
5. Cable outer diameters: 3.0mm, 2.0mm, and 0.9mm.
Specification
|
Mode |
Single mode |
Multimode |
|
|
Polish |
UPC |
APC |
PC |
|
Insertion Loss |
≤0.30dB |
≤0.20dB |
≤0.20dB |
|
Return Loss |
≥50dB |
≥60dB |
≥30dB |
|
Test Wavelength |
1310/1550nm |
850/1310nm |
|
|
Durability (500 Matings) |
≤0.2dB |
||
|
Operating Temperature |
-40℃~+60℃ |
||
|
Storage Temperature |
-45℃~+85℃ |
||
|
Fire Resistant |
IEC 60794-2-30 |
||
|
Standards-Compliant |
ROHS, IEC and GR-326 |
||
|
Fiber type |
Single mode: |
(1)9/125-G652D |
(2)9/125-G655 |
(3)9/125-G657A, G657A2 |
(4)9/125-G657B3 |
|
|
Multimode: |
(5)50/125-OM2 |
(6)62.5/125-OM1 |
(7)50/125-OM3 |
(8)50/125-OM4 |
(9)50/125-OM5 |
|
|
Fiber Brand |
YOFC, Corning, Sumitomo, Fujikura |
|||||
|
Connector |
SC/PC, SC/APC, LC/PC, LC/APC, FC/PC, FC/APC, ST/PC, E2000/PC, E2000/APC, MU/PC, MTRJ/Female, MTRJ/Male, MPO/MTP, DIN/PC, SMA/PC, D4/PC |
|||||
|
Cord type |
Simplex, Duplex |
|||||
|
Cable diameter |
0.9mm, 1.2mm, 1.6mm, 1.8mm, 2.0mm, 2.8mm, 3.0mmm, 4.1mm |
|||||
|
Cable jacket |
PVC, OFNR, LSZH, OFNP |
|||||
|
Length (M) |
0.5m, 1m, 2m, 5m, 10m, 25m, 50m, 100m…Customized |
|||||

FAQ
Q: What precautions should I take when using LC Fiber Patch Cords?
The transmit and receive wavelengths of the optical modules at both ends of the fiber optic patch cable must match. This means the modules must have the same wavelength. A simple way to distinguish them is by ensuring the modules have the same color. Generally, short-wavelength optical modules use multimode fiber, and long-wavelength optical modules use single-mode fiber to ensure data transmission. Avoid excessive twisting and looping of optical fibers during use, as this increases light attenuation during transmission. Always protect the fiber optic connectors with protective covers during use. Dust and oil can affect fiber coupling. If the fiber optic connectors become dirty, clean them with a cotton swab dipped in alcohol; otherwise, communication quality will be affected.
1. Before use LC Fiber Patch Cords, clean the ceramic ferrule and end face of the fiber optic patch cable with alcohol and cotton wool.
2. The minimum twist radius of the optical fiber used should be no less than 150mm.
3. Protect the ferrule and end face from scratches and contamination. Replace the dust cap immediately after removal.
4. Do not look directly at the fiber end face during laser signal transmission.
5. If damaged by human intervention or other unavoidable factors, promptly replace the damaged fiber optic patch cord.
6. Before installation, carefully read the instructions and perform installation and commissioning under the guidance of the manufacturer's or distributor's engineers.
7. If the fiber optic network or system exhibits abnormalities, perform a troubleshooting test to verify each patch cord individually. To verify or troubleshoot patch cord defects, first perform a continuity test, typically using a visible laser pointer to illuminate the entire fiber link. Alternatively, use an accurate fiber optic insertion loss meter to test each component. If the values are within the acceptable range, the patch cord indicates normal operation; otherwise, it fails.